Filters
Close

Cable & Power Management

View as
Sort by
Display per page

1000/2 Transformer Twin Outlet Rating 1Kva Continuous 500va

Tool Rating 1Kva.
Output Sockets. 2 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 Kv.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

£84.55 incl VAT

10K16 Transformer Six Outlet 10Kva 230V

Transformer for operation from single phase 230V mains supplies providing 110V Center Tapped Earth (CTE) output for the operation of portable tools, lighting and other construction site equipment.

It is designed to provide power of 10kVA through a number of output socket options.

The unit has 4 x 16A sockets and 2 x 32A sockets.

- heavy-duty sheet steel enclosure to IP23
- Manufactured generally to BS4363
- MCB overload protection for both the input and outputs
- Output sockets to BS EN 60309 / IEC 60309 (Previously BS4343)
- M5 Stud input terminals to accept your cabling

£576.38 incl VAT

10K36 Transformer Six Outlet 10Kva 400V

Transformer for operation from three phase 400V supply providing 110V Center Tapped Earth (CTE) output for the operation of portable tools, lighting and other construction site equipment.

It is designed to provide power of 10kVA through a number of output socket options.

The unit has 4 x 16A sockets and 2 x 32A sockets.

- Heavy-duty sheet steel enclosure to IP23
- Manufactured generally to BS 4363
- MCB overload protection for both the input and outputs
- Output sockets to BS EN 60309 / IEC 60309 (Previously BS 4343)
- M5 Stud input terminals to accept your cabling

£714.49 incl VAT

13A Fuses (Pack of 4)

13amp fuses (Pack of 4).
Suitable for appliances up to 3120 watts.

£1.19 incl VAT

1500/2 Transformer Twin Outlet Rating 1.50Kva Continuous 750va

Tool Rating 1.50 Kva.
Output Sockets. 2 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 Kv.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

£98.19 incl VAT

2 Way Unfused Adaptor

This handy two way adaptor converts one socket to two and is ideal for use in small spaces. The adaptor is unfused.

£1.29 incl VAT

2250/2 Transformer Twin Outlet Rating 2.25Kva Continuous 1.125kva

Tool Rating 2.25Kva.
Output Sockets. 2 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 Kv.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

£101.91 incl VAT

2-Gang Switched Socket Outlet + USB Charger 13 Amp

The Masterplug 822U is a 2-Gang switched socket with outboard rockers and 2 x type A USB sockets. It is ideal for charging iPad, iPhone, tablets, mobiles, cameras and more.

The socket outlet has a minimum mounting box depth of 25mm, making it ideal for retrofit. It is twin earth fitted as standard to allow a double Earth facility for installations requiring high integrity protective connection Ref. BS 7671:2008.

Manufactured to BS 5733 and BS EN 50950.

£10.15 incl VAT