5Kva Triple Outlet Transformer

The Faithfull TRAN5 is designed for use on the worksite, or anywhere where a 110 volt supply is required, to provide power to industrial powertools.

This 110 Volt transformer has 3 outlets 2 x 16 Amp and 1 x 32 Amp and has a heavy-duty GRP waterproof case which is rated to IP44, making it fully weatherproof and therefore suitable for use in most types of outdoor and worksite conditions.

This Faithfull 5 Kva transformer has a great safety features include a re-settable thermal overload protection function and a rubber cable fitted with BS approved 13 Amp rubber plug.

Not suitable for use on 110v heaters where a continuous load is required.

£243.00 incl VAT

10K16 Transformer Six Outlet 10Kva 230V

Transformer for operation from single phase 230V mains supplies providing 110V Center Tapped Earth (CTE) output for the operation of portable tools, lighting and other construction site equipment.

It is designed to provide power of 10kVA through a number of output socket options.

The unit has 4 x 16A sockets and 2 x 32A sockets.

- heavy-duty sheet steel enclosure to IP23
- Manufactured generally to BS4363
- MCB overload protection for both the input and outputs
- Output sockets to BS EN 60309 / IEC 60309 (Previously BS4343)
- M5 Stud input terminals to accept your cabling

£576.00 incl VAT

Transformer 1.5 Kva Single Outlet

The Faithfull TRAN15 is designed for use on the worksite to provide power to industrial powertools.
This single outlet 110 Volt 16amp transformer has a heavy-duty GRP weatherproof case which is rated to IP44, making it fully weatherproof and therefore suitable for use in most types of outdoor and worksite conditions.

This Faithfull 1.5 Kva transformer has great safety features that include a resettable thermal overload protection function and a heavy-duty rubber cable fitted with a BS approved 13 amp rubber plug.

Not suitable for use on 110v heaters.

£74.00 incl VAT

Transformer 3.3kva Dual Socket

The Faithfull Power Plus TRAN33A is a 16 Amp 3.3Kva Twin Outlet transformer, ideal for site use.

It has a heavy-duty GRP weatherproof case which is rated to IP44. It has a resettable thermal overload protection and is fitted with BS approved 13 amp plug. It also includes a unique blue LED ‘Power On’ indicator, which provides the user with an ‘at a glance’ confirmation that the unit is live.


This model has 2 x 110V 16 Amp sockets.

NOT suitable for use on 110v heaters where a continuous load is required.

£78.00 incl VAT

750/1 Transformer Single Outlet Rating 750va Continuous 375va

Tool Rating 750va.
Output Sockets. 1 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS EN60309 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 Kv.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

£80.00 incl VAT

2250/2 Transformer Twin Outlet Rating 2.25Kva Continuous 1.125kva

Tool Rating 2.25Kva.
Output Sockets. 2 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 Kv.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

£101.00 incl VAT

1000/2 Transformer Twin Outlet Rating 1Kva Continuous 500va

Tool Rating 1Kva.
Output Sockets. 2 x 16amp.

Transformer Specifications

Input 240 volts 50Hz single phase. Complete with 2 metres of 3-core flexible cable to BS6500 for connection to mains supply and a 13 amp plug.

Output 110 volts. Centre tapped and earth screen between primary and secondary windings which is bonded to the centre tap of the secondary winding, the earth pin on each output socket and earth core of the mains input plugs and sockets.

BS4343 flush type sockets with spring flap covers fitted as standard. Units are protected by suitably rated thermal overload cut-outs.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 Kv.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

£84.00 incl VAT

Thermal Reset Switch For FPPTRAN33A

This Faithfull Power Plus replacement Thermal Reset Switch is suitable for the FPPTRAN33A Dual Socket Transformer.

£6.00 incl VAT

5003/3 Transformer Triple Outlet Rating 5 Kva Continuous 2.5kva

Carroll & Meynell transformers are primarily for use when using portable electric tools on outdoor sites.

They are manufactured to BS EN 61558 and have thermal overload protection and with BS EN 60309 output sockets as standard. They have a glass reinforced polyester case and input flex and 13 amp plug. The 5Kva model is without a fitted plug, max input current 23amp.

The Carroll & Meynell transformers are completely encapsulated for extra weatherproofing .

These transformers are rated for intermittent operation at their maximum listed power capability for a duty cycle of 25%. i.e. 5 minutes ON 15 minutes OFF. They may be used in a continuous operation mode at a rating of 50% of their maximum capability. E.g. a 3.3Kva unit may be operated continuously at 1.65Kva.

2 x 16 Amp outlets , 1 x 32 Amp outlet

Intermittent transformer

This item shipped without an input plug. Maximum input current 23A.

Portable Tool Transformer - Safety Instructions
1. The transformer will get warm in normal use, make sure that the heat will not damage any floor covering that it is standing on. It is not advisable to place the transformer onto carpet, vinyl floor covering, etc., and use at continuous rating for any length of time.

4. Although the transformer may be of insulated construction, it is not double insulated (class 2) and the earth pin of the output socket must be connected to the centre point of the secondary winding and to the transformer incoming earth.

2. The transformer may be fitted with an over temperature cut-out switch, in the event of this operating, let the unit cool down then reset the cut-out switch before using again.

5. Power tool transformers must not be tested as class 2 appliances on portable appliance testers, flash test only at 1.5 KV.

3. Check the transformer power rating against the power rating of the tool you are going to use. The transformer can supply portable tools in normal use up to the rating shown on the transformer and consultation with the above table. Care should be taken when using the transformer to supply constant loads, i.e. floodlights, wallpaper strippers etc. The transformer can only supply about half of its rated power to continuous load like this.

6. Power tool transformers have an inherent high inrush current, in the event of the fuse blowing on switch, check that the fuse in the input plug is suitably rated and is of the anti surge type. Miniature circuit breakers protecting the sockets should have a type 4 tripping characteristic.

£183.00 incl VAT